Novel solution to improve the moss bag technique in environmental biological monitoring
Low doses of radiation can stimulate growth in plants in general and in mosses in particular and thereby enhance the ability of mosses to absorb airborne elements in the moss bag technique. The effect of low-energy X-ray radiation on the growth of Barbula indica moss was experimentally investigate...
Na minha lista:
Principais autores: | , , , |
---|---|
Formato: | Research article |
Idioma: | English |
Publicado em: |
2025
|
Assuntos: | |
Acesso em linha: | https://scholar.dlu.edu.vn/handle/123456789/5784 http://doi.org/10.30638/eemj.2025.099 |
Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|
Thư viện lưu trữ: | Thư viện Trường Đại học Đà Lạt |
---|
id |
oai:scholar.dlu.edu.vn:123456789-5784 |
---|---|
record_format |
dspace |
spelling |
oai:scholar.dlu.edu.vn:123456789-57842025-10-07T01:49:49Z Novel solution to improve the moss bag technique in environmental biological monitoring Nguyễn, Thị Minh Sang Lê, Ngọc Triệu Nguyễn, An Sơn Le Hong Khiem, Truong Van Minh airborne elements, irradiated moss, low-energy X-ray, moss growth Low doses of radiation can stimulate growth in plants in general and in mosses in particular and thereby enhance the ability of mosses to absorb airborne elements in the moss bag technique. The effect of low-energy X-ray radiation on the growth of Barbula indica moss was experimentally investigated with 20 doses of 1 to 20 Gy with a 1 Gy increment. The results showed that doses from 2 to 16 Gy improved the growth of moss compared to non-irradiated control samples and that the 14 Gy dose provided the optimal stimulation in terms of morphological characteristics, weight gain, and total chlorophyll content of the phyllids in the treated moss. The 14 Gy dose was chosen to irradiate moss that was exposed to the monitoring environment. The concentrations of the elements absorbed from the air were measured using the total reflection X-ray fluorescence technique for irradiated, nonirradiated, and native moss samples. The results showed that irradiated moss had a significantly higher ability to absorb elements from the air than non-irradiated moss, but the absorption was generally lower than for native moss. Our findings show that lowdose (14 Gy) radiation treatment of mosses is promising as an effective method to improve the accuracy of environmental monitoring by the moss bag technique. 24 6 1273-1281 Khoa Vật lý và Kỹ thuật hạt nhân 5 Nguyễn Thị Minh Sang x 2025-09-18T05:20:52Z 2025-09-18T05:20:52Z 2025-06 Research article Bài báo đăng trên tạp chí thuộc ISI, bao gồm book chapter https://scholar.dlu.edu.vn/handle/123456789/5784 http://doi.org/10.30638/eemj.2025.099 en Environmental Engineering and Management Journal |
institution |
Thư viện Trường Đại học Đà Lạt |
collection |
Thư viện số |
language |
English |
topic |
airborne elements, irradiated moss, low-energy X-ray, moss growth |
spellingShingle |
airborne elements, irradiated moss, low-energy X-ray, moss growth Nguyễn, Thị Minh Sang Lê, Ngọc Triệu Nguyễn, An Sơn Le Hong Khiem, Truong Van Minh Novel solution to improve the moss bag technique in environmental biological monitoring |
description |
Low doses of radiation can stimulate growth in plants in general and in mosses in particular and thereby enhance the ability of
mosses to absorb airborne elements in the moss bag technique. The effect of low-energy X-ray radiation on the growth of Barbula
indica moss was experimentally investigated with 20 doses of 1 to 20 Gy with a 1 Gy increment. The results showed that doses
from 2 to 16 Gy improved the growth of moss compared to non-irradiated control samples and that the 14 Gy dose provided the
optimal stimulation in terms of morphological characteristics, weight gain, and total chlorophyll content of the phyllids in the
treated moss. The 14 Gy dose was chosen to irradiate moss that was exposed to the monitoring environment. The concentrations
of the elements absorbed from the air were measured using the total reflection X-ray fluorescence technique for irradiated, nonirradiated, and native moss samples. The results showed that irradiated moss had a significantly higher ability to absorb elements
from the air than non-irradiated moss, but the absorption was generally lower than for native moss. Our findings show that lowdose (14 Gy) radiation treatment of mosses is promising as an effective method to improve the accuracy of environmental
monitoring by the moss bag technique. |
format |
Research article |
author |
Nguyễn, Thị Minh Sang Lê, Ngọc Triệu Nguyễn, An Sơn Le Hong Khiem, Truong Van Minh |
author_facet |
Nguyễn, Thị Minh Sang Lê, Ngọc Triệu Nguyễn, An Sơn Le Hong Khiem, Truong Van Minh |
author_sort |
Nguyễn, Thị Minh Sang |
title |
Novel solution to improve the moss bag technique in environmental biological monitoring |
title_short |
Novel solution to improve the moss bag technique in environmental biological monitoring |
title_full |
Novel solution to improve the moss bag technique in environmental biological monitoring |
title_fullStr |
Novel solution to improve the moss bag technique in environmental biological monitoring |
title_full_unstemmed |
Novel solution to improve the moss bag technique in environmental biological monitoring |
title_sort |
novel solution to improve the moss bag technique in environmental biological monitoring |
publishDate |
2025 |
url |
https://scholar.dlu.edu.vn/handle/123456789/5784 http://doi.org/10.30638/eemj.2025.099 |
_version_ |
1845408767442681856 |