Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute

In this research, dose calculation and measurement from B10 (n,α) Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute have been reported. Calculation was carried out by using Monte Carlo method. Neutron activation technique using vanadium foil was employed to determine neutr...

Mô tả đầy đủ

Đã lưu trong:
Chi tiết về thư mục
Tác giả chính: Trịnh, Thị Tú Anh
Định dạng: Conference paper
Ngôn ngữ:Vietnamese
Được phát hành: 2022
Truy cập trực tuyến:http://scholar.dlu.edu.vn/handle/123456789/1641
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=49059303
Các nhãn: Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
Thư viện lưu trữ: Thư viện Trường Đại học Đà Lạt
id oai:scholar.dlu.edu.vn:123456789-1641
record_format dspace
spelling oai:scholar.dlu.edu.vn:123456789-16412022-12-22T07:59:12Z Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute Trịnh, Thị Tú Anh In this research, dose calculation and measurement from B10 (n,α) Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute have been reported. Calculation was carried out by using Monte Carlo method. Neutron activation technique using vanadium foil was employed to determine neutron flux at various positions in phantom from which neutron dose has been calculated using conversion factor. These calculations are basics for the dose determination research of the Boron Neutron Capture Therapy (BNCT) in Vietnam. 49 29 2022-12-22T07:23:12Z 2022-12-22T07:23:12Z 2017 Conference paper Bài báo đăng trên KYHT trong nước (có ISBN) http://scholar.dlu.edu.vn/handle/123456789/1641 https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=49059303 vi CONFERRENCE NUCLEAR PHYSICS AND RADIATION PHYSICS
institution Thư viện Trường Đại học Đà Lạt
collection Thư viện số
language Vietnamese
description In this research, dose calculation and measurement from B10 (n,α) Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute have been reported. Calculation was carried out by using Monte Carlo method. Neutron activation technique using vanadium foil was employed to determine neutron flux at various positions in phantom from which neutron dose has been calculated using conversion factor. These calculations are basics for the dose determination research of the Boron Neutron Capture Therapy (BNCT) in Vietnam.
format Conference paper
author Trịnh, Thị Tú Anh
spellingShingle Trịnh, Thị Tú Anh
Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute
author_facet Trịnh, Thị Tú Anh
author_sort Trịnh, Thị Tú Anh
title Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute
title_short Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute
title_full Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute
title_fullStr Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute
title_full_unstemmed Dose calculation and measurement from B10(n,α)Li7 reaction using filtered neutron beam at Dalat Nuclear Research Institute
title_sort dose calculation and measurement from b10(n,α)li7 reaction using filtered neutron beam at dalat nuclear research institute
publishDate 2022
url http://scholar.dlu.edu.vn/handle/123456789/1641
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=49059303
_version_ 1768306222462664704