PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP

A 13 MHz - normal conducting cavity for an rf implanter has been successfully developed at PEFP (Proton Engineering Frontier Project). It consists of an inductive coil, accelerating electrodes and a ground electrode for the inductor. Quality factor of 2074 and critical coupling were achieved at...

Mô tả đầy đủ

Đã lưu trong:
Chi tiết về thư mục
Tác giả chính: Trịnh, Thị Tú Anh
Định dạng: Conference object
Ngôn ngữ:Vietnamese
Được phát hành: 2023
Truy cập trực tuyến:http://scholar.dlu.edu.vn/handle/123456789/1659
https://epaper.kek.jp/IPAC2011/papers/mopc031.pdf
Các nhãn: Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
Thư viện lưu trữ: Thư viện Trường Đại học Đà Lạt
id oai:scholar.dlu.edu.vn:123456789-1659
record_format dspace
spelling oai:scholar.dlu.edu.vn:123456789-16592023-01-04T10:03:04Z PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP Trịnh, Thị Tú Anh A 13 MHz - normal conducting cavity for an rf implanter has been successfully developed at PEFP (Proton Engineering Frontier Project). It consists of an inductive coil, accelerating electrodes and a ground electrode for the inductor. Quality factor of 2074 and critical coupling were achieved at resonant frequency of 12.658MHz. Rf power of 1kW was forwarded to the cavity without any spark in the cavity. Beam test was then carried out with a 27keV helium beam generated from a Duoplasmatron ion source. The results showed that the helium beam was accelerated to final energy of 117 keV with energy spread of 1%. Detail experiments and results are addressed in this presentation. 2023-01-03T02:29:34Z 2023-01-03T02:29:34Z 2011 Conference object Bài báo đăng trên tạp chí quốc tế (có ISSN), bao gồm book chapter http://scholar.dlu.edu.vn/handle/123456789/1659 https://epaper.kek.jp/IPAC2011/papers/mopc031.pdf vi Proceedings of IPAC2011, San Sebastián, Spain
institution Thư viện Trường Đại học Đà Lạt
collection Thư viện số
language Vietnamese
description A 13 MHz - normal conducting cavity for an rf implanter has been successfully developed at PEFP (Proton Engineering Frontier Project). It consists of an inductive coil, accelerating electrodes and a ground electrode for the inductor. Quality factor of 2074 and critical coupling were achieved at resonant frequency of 12.658MHz. Rf power of 1kW was forwarded to the cavity without any spark in the cavity. Beam test was then carried out with a 27keV helium beam generated from a Duoplasmatron ion source. The results showed that the helium beam was accelerated to final energy of 117 keV with energy spread of 1%. Detail experiments and results are addressed in this presentation.
format Conference object
author Trịnh, Thị Tú Anh
spellingShingle Trịnh, Thị Tú Anh
PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP
author_facet Trịnh, Thị Tú Anh
author_sort Trịnh, Thị Tú Anh
title PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP
title_short PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP
title_full PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP
title_fullStr PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP
title_full_unstemmed PERFORMANCE OF A 13MHZ CAVITY FOR AN RF IMPLANTER AT PEFP
title_sort performance of a 13mhz cavity for an rf implanter at pefp
publishDate 2023
url http://scholar.dlu.edu.vn/handle/123456789/1659
https://epaper.kek.jp/IPAC2011/papers/mopc031.pdf
_version_ 1768306227426623488