Instrumentation for Measurement of the Energy Distribution of the RF Implanter

A microbeam production using the RF implanter at PEFP is in progress for research in material science. For this purpose, the energy spread of the beam less than 1% is required. A beam focusing system with a triplet quardrupole has been adopted. In order to measure the energy spread, we have dev...

وصف كامل

محفوظ في:
التفاصيل البيبلوغرافية
المؤلف الرئيسي: Trịnh, Thị Tú Anh
التنسيق: Conference object
اللغة:Vietnamese
منشور في: 2023
الوصول للمادة أونلاين:http://scholar.dlu.edu.vn/handle/123456789/1662
https://www.kns.org/files/pre_paper/7/536Tu%20Anh%20Trinh.pdf
الوسوم: إضافة وسم
لا توجد وسوم, كن أول من يضع وسما على هذه التسجيلة!
Thư viện lưu trữ: Thư viện Trường Đại học Đà Lạt
id oai:scholar.dlu.edu.vn:123456789-1662
record_format dspace
spelling oai:scholar.dlu.edu.vn:123456789-16622023-01-04T10:06:57Z Instrumentation for Measurement of the Energy Distribution of the RF Implanter Trịnh, Thị Tú Anh A microbeam production using the RF implanter at PEFP is in progress for research in material science. For this purpose, the energy spread of the beam less than 1% is required. A beam focusing system with a triplet quardrupole has been adopted. In order to measure the energy spread, we have developed a simple analyzing system using the disperse power of a deflecting magnet in the transport line. The instruments have been designed and installed to the beam diagnostic station which is located image position of the deflecting magnet system. Detailed work will be presented in this paper. 21-22 2023-01-03T02:37:33Z 2023-01-03T02:37:33Z 2010 Conference object Bài báo đăng trên KYHT quốc tế (có ISBN) http://scholar.dlu.edu.vn/handle/123456789/1662 https://www.kns.org/files/pre_paper/7/536Tu%20Anh%20Trinh.pdf vi Transactions of the Korean Nuclear Society Autumn Meeting Jeju, Korea
institution Thư viện Trường Đại học Đà Lạt
collection Thư viện số
language Vietnamese
description A microbeam production using the RF implanter at PEFP is in progress for research in material science. For this purpose, the energy spread of the beam less than 1% is required. A beam focusing system with a triplet quardrupole has been adopted. In order to measure the energy spread, we have developed a simple analyzing system using the disperse power of a deflecting magnet in the transport line. The instruments have been designed and installed to the beam diagnostic station which is located image position of the deflecting magnet system. Detailed work will be presented in this paper.
format Conference object
author Trịnh, Thị Tú Anh
spellingShingle Trịnh, Thị Tú Anh
Instrumentation for Measurement of the Energy Distribution of the RF Implanter
author_facet Trịnh, Thị Tú Anh
author_sort Trịnh, Thị Tú Anh
title Instrumentation for Measurement of the Energy Distribution of the RF Implanter
title_short Instrumentation for Measurement of the Energy Distribution of the RF Implanter
title_full Instrumentation for Measurement of the Energy Distribution of the RF Implanter
title_fullStr Instrumentation for Measurement of the Energy Distribution of the RF Implanter
title_full_unstemmed Instrumentation for Measurement of the Energy Distribution of the RF Implanter
title_sort instrumentation for measurement of the energy distribution of the rf implanter
publishDate 2023
url http://scholar.dlu.edu.vn/handle/123456789/1662
https://www.kns.org/files/pre_paper/7/536Tu%20Anh%20Trinh.pdf
_version_ 1768306228393410560