Study for determining the correction parameters in neutron capture cross section measurement

The aim of this study was to determine correction parameters to improve the accuracy in measurements of the neutron capture cross-section on filtered neutron beams at Dalat nuclear research reactor. Computer codes to calculate these factors for effect of resonance capture at low energy background, m...

Mô tả đầy đủ

Đã lưu trong:
Chi tiết về thư mục
Tác giả chính: Trịnh, Thị Tú Anh
Định dạng: Conference object
Ngôn ngữ:Vietnamese
Được phát hành: 2023
Truy cập trực tuyến:http://scholar.dlu.edu.vn/handle/123456789/1670
https://inis.iaea.org/search/search.aspx?orig_q=RN:41067197
Các nhãn: Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
Thư viện lưu trữ: Thư viện Trường Đại học Đà Lạt
id oai:scholar.dlu.edu.vn:123456789-1670
record_format dspace
spelling oai:scholar.dlu.edu.vn:123456789-16702023-01-04T10:18:35Z Study for determining the correction parameters in neutron capture cross section measurement Trịnh, Thị Tú Anh The aim of this study was to determine correction parameters to improve the accuracy in measurements of the neutron capture cross-section on filtered neutron beams at Dalat nuclear research reactor. Computer codes to calculate these factors for effect of resonance capture at low energy background, multi scattering, and shelf shielding have been developed based on the methods of Monte - Carlo, Neutron transmission and Unfolding. The calculated and experimental results of neutron background spectra for 53.9 keV and 148.3 keV filtered neutron beams and the correction factors for nuclei of 197Au, 139La, 191Ir, 193Ir, and 152Sm are reported. 41 24 2023-01-03T06:54:59Z 2023-01-03T06:54:59Z 2008 Conference object Bài báo đăng trên KYHT trong nước (có ISBN) http://scholar.dlu.edu.vn/handle/123456789/1670 https://inis.iaea.org/search/search.aspx?orig_q=RN:41067197 vi Proceedings of the 7th National Conference on Nuclear Science and Technology 2008
institution Thư viện Trường Đại học Đà Lạt
collection Thư viện số
language Vietnamese
description The aim of this study was to determine correction parameters to improve the accuracy in measurements of the neutron capture cross-section on filtered neutron beams at Dalat nuclear research reactor. Computer codes to calculate these factors for effect of resonance capture at low energy background, multi scattering, and shelf shielding have been developed based on the methods of Monte - Carlo, Neutron transmission and Unfolding. The calculated and experimental results of neutron background spectra for 53.9 keV and 148.3 keV filtered neutron beams and the correction factors for nuclei of 197Au, 139La, 191Ir, 193Ir, and 152Sm are reported.
format Conference object
author Trịnh, Thị Tú Anh
spellingShingle Trịnh, Thị Tú Anh
Study for determining the correction parameters in neutron capture cross section measurement
author_facet Trịnh, Thị Tú Anh
author_sort Trịnh, Thị Tú Anh
title Study for determining the correction parameters in neutron capture cross section measurement
title_short Study for determining the correction parameters in neutron capture cross section measurement
title_full Study for determining the correction parameters in neutron capture cross section measurement
title_fullStr Study for determining the correction parameters in neutron capture cross section measurement
title_full_unstemmed Study for determining the correction parameters in neutron capture cross section measurement
title_sort study for determining the correction parameters in neutron capture cross section measurement
publishDate 2023
url http://scholar.dlu.edu.vn/handle/123456789/1670
https://inis.iaea.org/search/search.aspx?orig_q=RN:41067197
_version_ 1768306231096639488