The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector
The high quality measurements of neutron energy spectra are required in various fields of research and applications. However, in many cases the contribution of gamma background causes the inaccuracy of neutron spectrum. Therefore, the discrimination of gamma-ray events in neutron spectrum is necessa...
Đã lưu trong:
Những tác giả chính: | , , , , |
---|---|
Định dạng: | Journal article |
Ngôn ngữ: | English |
Được phát hành: |
ietnam Atomic Energy Society (VAES)
2023
|
Những chủ đề: | |
Truy cập trực tuyến: | https://scholar.dlu.edu.vn/handle/123456789/2548 |
Các nhãn: |
Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
|
Thư viện lưu trữ: | Thư viện Trường Đại học Đà Lạt |
---|
id |
oai:scholar.dlu.edu.vn:123456789-2548 |
---|---|
record_format |
dspace |
spelling |
oai:scholar.dlu.edu.vn:123456789-25482023-06-10T12:43:11Z The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector Phan, Văn Chuân Đặng, Hồng Ngọc Quý Phạm, Ngọc Tuấn Trương, Thị Thu Hường Nguyễn, Nhị Điền Pulse Shaping Discriminator (PSD) Digital Signal Processing (DSP) EJ-301 scintillator The high quality measurements of neutron energy spectra are required in various fields of research and applications. However, in many cases the contribution of gamma background causes the inaccuracy of neutron spectrum. Therefore, the discrimination of gamma-ray events in neutron spectrum is necessary. In this article, an algorithm for digital implementation of the charge-comparison method for n/γ discrimination based on Digital Signal Processing technique is described. Furthermore, the APX-500 board was used as a hardware for the development of a Pulse Shape Disciminator, and is equipped with ADC ADM-414 14 bit-100 MSPS. The fully system has been tested with EJ-301 detector, using 252Cf neutron source. 7 2 51-55 2023-06-10T12:43:06Z 2023-06-10T12:43:06Z 2017 Journal article Bài báo đăng trên tạp chí trong nước (có ISSN), bao gồm book chapter https://scholar.dlu.edu.vn/handle/123456789/2548 en Nuclear Science and Technology (NST) 1810-5408 [1]. Moslem Amiri, Neutron/gamma-ray measurement and discrimination, PhD thesis, 2014. [2]. M. L. Roush, M. A. Wilson, and W. F. Hornyak, “Pulse shape discrimination,” Nucl. Instruments Methods, vol. 31, no. 1, pp. 112–124, 1964. [3]. E. Bayat, N. Divani-Vais, M. M. Firoozabadi, and N. Ghal-Eh, “A comparative study on neutron-gamma discrimination with NE213 and UGLLT scintillators using zero-crossing method,” Radiat. Phys. Chem., vol. 81, no. 3, pp. 217–220, 2012. [4]. J. Cerny, Z. Dolezal, M. P. Ivanov, E. S. Kuzmin, J. Svejda, and I. Wilhelm, “Study of neutron response and n--γ discrimination by charge comparison method for small liquid scintillation detector,” Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. Assoc. Equip., vol. 527, no. 3, pp. 512–518, 2004. [5]. G. Liu, M. J. Joyce, X. Ma, and M. D. Aspinall, “A digital method for the discrimination of neutrons and rays with organic scintillation detectors using frequency gradient analysis,” Nucl. Sci. IEEE Trans., vol. 57, no. 3, pp. 1682–1691, 2010. [6]. Takaku, D., Oishi, T. & Baba, M. (2011). Development of neutron-gamma discrimination technique using pattern-recognition method with digital signal processing. Nuclear Science and Technology, 1, 210-213. ietnam Atomic Energy Society (VAES) ietnam Atomic Energy Society (VAES) |
institution |
Thư viện Trường Đại học Đà Lạt |
collection |
Thư viện số |
language |
English |
topic |
Pulse Shaping Discriminator (PSD) Digital Signal Processing (DSP) EJ-301 scintillator |
spellingShingle |
Pulse Shaping Discriminator (PSD) Digital Signal Processing (DSP) EJ-301 scintillator Phan, Văn Chuân Đặng, Hồng Ngọc Quý Phạm, Ngọc Tuấn Trương, Thị Thu Hường Nguyễn, Nhị Điền The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector |
description |
The high quality measurements of neutron energy spectra are required in various fields of research and applications. However, in many cases the contribution of gamma background causes the inaccuracy of neutron spectrum. Therefore, the discrimination of gamma-ray events in neutron spectrum is necessary. In this article, an algorithm for digital implementation of the charge-comparison method for n/γ discrimination based on Digital Signal Processing technique is described. Furthermore, the APX-500 board was used as a hardware for the development of a Pulse Shape Disciminator, and is equipped with ADC ADM-414 14 bit-100 MSPS. The fully system has been tested with EJ-301 detector, using 252Cf neutron source. |
format |
Journal article |
author |
Phan, Văn Chuân Đặng, Hồng Ngọc Quý Phạm, Ngọc Tuấn Trương, Thị Thu Hường Nguyễn, Nhị Điền |
author_facet |
Phan, Văn Chuân Đặng, Hồng Ngọc Quý Phạm, Ngọc Tuấn Trương, Thị Thu Hường Nguyễn, Nhị Điền |
author_sort |
Phan, Văn Chuân |
title |
The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector |
title_short |
The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector |
title_full |
The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector |
title_fullStr |
The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector |
title_full_unstemmed |
The design and fabricate a pulse shape discriminator apply signal processing method using EJ-301 detector |
title_sort |
design and fabricate a pulse shape discriminator apply signal processing method using ej-301 detector |
publisher |
ietnam Atomic Energy Society (VAES) |
publishDate |
2023 |
url |
https://scholar.dlu.edu.vn/handle/123456789/2548 |
_version_ |
1778233880318312448 |