Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation
A specific dynamic osmotic membrane bioreactor (DR-OMBR) in low-speed rolling motion was designed to alleviate membrane fouling. Using a low rotation speed (2 rpm) together with the cross-flow velocity in this designed DR-OMBR, the shear stress (−1.57 × 10−4 N/m2) and the centrifugal force (1.31 × 1...
Đã lưu trong:
Những tác giả chính: | , , , , |
---|---|
Định dạng: | Journal article |
Ngôn ngữ: | Vietnamese |
Được phát hành: |
2023
|
Những chủ đề: | |
Truy cập trực tuyến: | https://scholar.dlu.edu.vn/handle/123456789/2980 https://www.sciencedirect.com/science/article/pii/S0376738822008183 |
Các nhãn: |
Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
|
Thư viện lưu trữ: | Thư viện Trường Đại học Đà Lạt |
---|
id |
oai:scholar.dlu.edu.vn:123456789-2980 |
---|---|
record_format |
dspace |
spelling |
oai:scholar.dlu.edu.vn:123456789-29802023-09-28T02:55:53Z Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation Chang, Hau-Ming Chen, Shiao-Shing Chang, Wen-Shing Nguyễn, Thị Xuân Quỳnh Nguyen Cong Nguyen Osmotic membrane bioreactor; Membrane fouling; Rolling module; Membrane distillation; Forward osmosis A specific dynamic osmotic membrane bioreactor (DR-OMBR) in low-speed rolling motion was designed to alleviate membrane fouling. Using a low rotation speed (2 rpm) together with the cross-flow velocity in this designed DR-OMBR, the shear stress (−1.57 × 10−4 N/m2) and the centrifugal force (1.31 × 10−4 N) were generated to reduce the attachment of foulant to the membrane surface and achieve a relatively stable water flux. A parallel experiment indicated that the water flux of the conventional OMBR (without rotation) was 10% lower than that of the DR-OMBR, and total organic carbon and phosphate removals still achieved 99.9 and 97.0%, respectively. The ammonium rejection was slightly lower as a result of the Donna effect. Furthermore, compared to rotation speeds (0–5 rpm), the rotation speed of 2 rpm achieved better water flux (6.4 LMH) and lower reversal salt diffusion (3.7 gMH) because the centrifugal force had a positive effect on the reversal salt flux and a negative impact on the water flux, and a higher rotation speed could generate a considerable centrifugal force to limit the water flux and increase the reverse salt flux. Furthermore, the mitigation of membrane fouling was further confirmed by the relatively low amount of extracellular polymeric substances (EPS) and soluble microbial products (SMP) on the membrane surface of the DR-OMBR. 2023-09-28T02:55:49Z 2023-09-28T02:55:49Z 2022 Journal article Bài báo đăng trên tạp chí thuộc ISI, bao gồm book chapter 0376-7388 https://scholar.dlu.edu.vn/handle/123456789/2980 doi.org/10.1016/j.memsci.2022.121073 https://www.sciencedirect.com/science/article/pii/S0376738822008183 vi |
institution |
Thư viện Trường Đại học Đà Lạt |
collection |
Thư viện số |
language |
Vietnamese |
topic |
Osmotic membrane bioreactor; Membrane fouling; Rolling module; Membrane distillation; Forward osmosis |
spellingShingle |
Osmotic membrane bioreactor; Membrane fouling; Rolling module; Membrane distillation; Forward osmosis Chang, Hau-Ming Chen, Shiao-Shing Chang, Wen-Shing Nguyễn, Thị Xuân Quỳnh Nguyen Cong Nguyen Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
description |
A specific dynamic osmotic membrane bioreactor (DR-OMBR) in low-speed rolling motion was designed to alleviate membrane fouling. Using a low rotation speed (2 rpm) together with the cross-flow velocity in this designed DR-OMBR, the shear stress (−1.57 × 10−4 N/m2) and the centrifugal force (1.31 × 10−4 N) were generated to reduce the attachment of foulant to the membrane surface and achieve a relatively stable water flux. A parallel experiment indicated that the water flux of the conventional OMBR (without rotation) was 10% lower than that of the DR-OMBR, and total organic carbon and phosphate removals still achieved 99.9 and 97.0%, respectively. The ammonium rejection was slightly lower as a result of the Donna effect. Furthermore, compared to rotation speeds (0–5 rpm), the rotation speed of 2 rpm achieved better water flux (6.4 LMH) and lower reversal salt diffusion (3.7 gMH) because the centrifugal force had a positive effect on the reversal salt flux and a negative impact on the water flux, and a higher rotation speed could generate a considerable centrifugal force to limit the water flux and increase the reverse salt flux. Furthermore, the mitigation of membrane fouling was further confirmed by the relatively low amount of extracellular polymeric substances (EPS) and soluble microbial products (SMP) on the membrane surface of the DR-OMBR. |
format |
Journal article |
author |
Chang, Hau-Ming Chen, Shiao-Shing Chang, Wen-Shing Nguyễn, Thị Xuân Quỳnh Nguyen Cong Nguyen |
author_facet |
Chang, Hau-Ming Chen, Shiao-Shing Chang, Wen-Shing Nguyễn, Thị Xuân Quỳnh Nguyen Cong Nguyen |
author_sort |
Chang, Hau-Ming |
title |
Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
title_short |
Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
title_full |
Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
title_fullStr |
Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
title_full_unstemmed |
Exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
title_sort |
exploration of the dynamic osmotic membrane bioreactor in low-speed rolling motion for membrane fouling mitigation |
publishDate |
2023 |
url |
https://scholar.dlu.edu.vn/handle/123456789/2980 https://www.sciencedirect.com/science/article/pii/S0376738822008183 |
_version_ |
1778792466449694720 |