Determination of Neutron Temperature at Irradiation Positions of IREN

he IREN facility, located in the Frank Laboratory of Neutron Physics at the Joint Institute for Nuclear Research, is an electron accelerator-driven source of intense pulsed neutrons with thermal and resonance energies. It is designed for the application of neutron time-of-flight spectroscopy, which...

詳細記述

保存先:
書誌詳細
主要な著者: LTM Nhat, VD Cong, LH Khiem, SB Borzakov, A Yu Dmitriev, VN Shvetsov, VV Lobachev, OS Philippova, AO Zontikov, PV Sedyshev, TN Toan, THB Phi, PT Thanh, DV Trung, NT Binh, NT X Thai, Nguyễn, An Sơn
フォーマット: Research article
言語:English
出版事項: 2025
オンライン・アクセス:https://scholar.dlu.edu.vn/handle/123456789/5785
https://doi.org/10.1134/S1547477124702327
タグ: タグ追加
タグなし, このレコードへの初めてのタグを付けませんか!
Thư viện lưu trữ: Thư viện Trường Đại học Đà Lạt
その他の書誌記述
要約:he IREN facility, located in the Frank Laboratory of Neutron Physics at the Joint Institute for Nuclear Research, is an electron accelerator-driven source of intense pulsed neutrons with thermal and resonance energies. It is designed for the application of neutron time-of-flight spectroscopy, which is utilized for measuring neutron interaction cross sections and conducting elemental analysis through (epi)thermal and resonance neutron activation of samples. For the intended purposes, the precise determination of the neutron temperature at the irradiation positions is crucial. This report introduces a methodology for accurately determining the Maxwellian temperature (TM) of the thermal neutron distribution at the irradiation positions located on the outer wall of IREN’s neutron production target chamber.