Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays

The sprout inhibition of onion and potato by low energy X-rays was investigated using a 160 kV X-ray irradiation system to determine optimal irradiation conditions. The sprouting of onion was effectively suppressed by irradiating 20 Gy at a depth of 3.2 mm from root side for small onion and at 8.0...

Mô tả đầy đủ

Đã lưu trong:
Chi tiết về thư mục
Những tác giả chính: Nguyễn, Thị Nguyệt H, Nguyễn, Thị Thùy Linh, Nguyễn, An Sơn, Nguyễn, Thị Minh Sang, Phạm, Thị Ngọc H, Lê, Đoàn Đình Đức, Tamikazu Kume
Định dạng: Research article
Ngôn ngữ:English
Được phát hành: Japan Radioisotope Association 2023
Những chủ đề:
Truy cập trực tuyến:https://scholar.dlu.edu.vn/handle/123456789/2801
Các nhãn: Thêm thẻ
Không có thẻ, Là người đầu tiên thẻ bản ghi này!
Thư viện lưu trữ: Thư viện Trường Đại học Đà Lạt
id oai:scholar.dlu.edu.vn:123456789-2801
record_format dspace
spelling oai:scholar.dlu.edu.vn:123456789-28012024-04-10T10:48:22Z Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays Nguyễn, Thị Nguyệt Hà Nguyễn, Thị Thùy Linh Nguyễn, An Sơn Nguyễn, Thị Minh Sang Phạm, Thị Ngọc Hà Lê, Đoàn Đình Đức Tamikazu Kume low energy X-rays, sprout inhibition, depth dose, onion, potato The sprout inhibition of onion and potato by low energy X-rays was investigated using a 160 kV X-ray irradiation system to determine optimal irradiation conditions. The sprouting of onion was effectively suppressed by irradiating 20 Gy at a depth of 3.2 mm from root side for small onion and at 8.0 mm depth for large onion, respectively. For potato, double-sided irradiation was necessary to irradiate the entire potato because the buds were distributed throughout the entire potato. Irradiation on double-sided at a depth of 8.0 mm with 50 Gy (60 Gy at 5.4 mm) effectively inhibited the sprouting. The throughput calculated to be 80.9 kg/h for large onion, 34.1 kg/h for small onion, and 9.9 kg/h for potato at a distance of 350 mm from the focal point of source. Dose uniformity (Dmax at surface/Dmin at 8.0 mm depth) of potato in case of double-sided irradiation was improved from 3.6 (182 Gy/50 Gy) to 1.2 (58 Gy/50 Gy) by using an aluminum 1.0 mm filter (F1) to cut off low energy X-rays, whereas the throughput capacity decreased from 9.9 kg/h to 7.4 kg/h. 72 2 163-172 Khoa Vật lý và Kỹ thuật hạt nhân 7 Nguyễn, Thị Minh Sang X 2023-07-18T07:59:47Z 2023-07-18T07:59:47Z 2023 Research article Bài báo đăng trên tạp chí quốc tế (có ISSN), bao gồm book chapter https://scholar.dlu.edu.vn/handle/123456789/2801 10.3769/radioisotopes.72.163 en Đề tài KH&CN International Atomic Energy Agency (IAEA) CRP RADIOISOTOPES 1884-4111 B2020-DLA-02 CRP D61025 Japan Radioisotope Association Japan Radioisotope Association
institution Thư viện Trường Đại học Đà Lạt
collection Thư viện số
language English
topic low energy X-rays, sprout inhibition, depth dose, onion, potato
spellingShingle low energy X-rays, sprout inhibition, depth dose, onion, potato
Nguyễn, Thị Nguyệt Hà
Nguyễn, Thị Thùy Linh
Nguyễn, An Sơn
Nguyễn, Thị Minh Sang
Phạm, Thị Ngọc Hà
Lê, Đoàn Đình Đức
Tamikazu Kume
Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays
description The sprout inhibition of onion and potato by low energy X-rays was investigated using a 160 kV X-ray irradiation system to determine optimal irradiation conditions. The sprouting of onion was effectively suppressed by irradiating 20 Gy at a depth of 3.2 mm from root side for small onion and at 8.0 mm depth for large onion, respectively. For potato, double-sided irradiation was necessary to irradiate the entire potato because the buds were distributed throughout the entire potato. Irradiation on double-sided at a depth of 8.0 mm with 50 Gy (60 Gy at 5.4 mm) effectively inhibited the sprouting. The throughput calculated to be 80.9 kg/h for large onion, 34.1 kg/h for small onion, and 9.9 kg/h for potato at a distance of 350 mm from the focal point of source. Dose uniformity (Dmax at surface/Dmin at 8.0 mm depth) of potato in case of double-sided irradiation was improved from 3.6 (182 Gy/50 Gy) to 1.2 (58 Gy/50 Gy) by using an aluminum 1.0 mm filter (F1) to cut off low energy X-rays, whereas the throughput capacity decreased from 9.9 kg/h to 7.4 kg/h.
format Research article
author Nguyễn, Thị Nguyệt Hà
Nguyễn, Thị Thùy Linh
Nguyễn, An Sơn
Nguyễn, Thị Minh Sang
Phạm, Thị Ngọc Hà
Lê, Đoàn Đình Đức
Tamikazu Kume
author_facet Nguyễn, Thị Nguyệt Hà
Nguyễn, Thị Thùy Linh
Nguyễn, An Sơn
Nguyễn, Thị Minh Sang
Phạm, Thị Ngọc Hà
Lê, Đoàn Đình Đức
Tamikazu Kume
author_sort Nguyễn, Thị Nguyệt Hà
title Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays
title_short Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays
title_full Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays
title_fullStr Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays
title_full_unstemmed Effective Irradiation for Sprout Inhibition of Onion and Potato by Low Energy X-rays
title_sort effective irradiation for sprout inhibition of onion and potato by low energy x-rays
publisher Japan Radioisotope Association
publishDate 2023
url https://scholar.dlu.edu.vn/handle/123456789/2801
_version_ 1798256952129617920